法國power sonic蓄電池PS-12260NB 12V26AH
法國power sonic蓄電池PS-12260NB 12V26AH
Power-Sonic一直是主導力量在電池業務超過46年。由于我們的承諾我們公司蓬勃發展提供高質量的成本有效的電池,支持水平的服務是的。
我們驕傲我們的靈活性和能力迅速采取行動為市場帶來新的行業產品。我們很自豪持有ISO 9001認證覆蓋我們的組織的各個方面。
How long will my battery last?
The lifespan of a battery will vary considerably with how it is used, how it is maintained and charged, temperature, and other factors.
How to connect a battery in Series?
The positive terminal of the first battery is connected to the negative terminal of the second battery, the positive terminal of the second is connected to the negative of the third, etc. The voltage of the assembled battery is the sum of the battery voltages of the individual batteries. So the batteries are connected: + to - to + to - to + to -, etc. The capacity of the battery is unchanged.
此種供電系統的缺點:
此供電系統要求直流元器件;對器件滅弧要求高;由于電壓高,無過零點,對安全性要求高。
八、高壓直流供電系統解決方案三
高電壓直流供電系統方案三與方案二供電系統是類似的,所不同的是,方案三供電系統增加升壓電路,將直流輸出電壓提高到400V(此種類似的供電系統在移動公司有實驗點,直流電壓350V)。是針對專門的高壓服務器電源,目前此服務器尚在研制之中,由于系統輸出電壓高,對目前大量在使用的服務器有些是不可用的,但由于某些優點突出,可能成為未來的一種發展的趨勢。系統圖見圖9。
此方案供電系統的優點:
模塊化供電,電池直接連接負載,母線電源不間斷;電源效率高,較節能;輸出為直流無率因數與諧波問題,具備大負載能力;供電電纜細,節省成本與空間。
此方案供電系統的缺點:
故障的安裝拆除易造成拉弧;對安全的要求高,器件的要求也高。
結論
電信技術的迅速發展推動了電源設備技術的進步,高電壓直流供電系統方案二與方案三因為其可靠性高,效率高,特別適用于設備功率較大的場合的IDC機房供電。方案二適合于目前的服務器,也是目前IDC機房供電的改造相對較適合的方案,方案三可能是一種IDC機房設備供電的發展趨勢。IDC機房供電系統到底是什么,還值得深入探討與研究,終總會找到一種適合的方案。
How to connect a battery in Parallel?
The positive terminal of the first battery is connected to the positive terminal of the second battery, the positive terminal of the second is connected to the positive of the third, etc. and The negative terminal of the first battery is connected to the negative terminal of the second battery, the negative terminal of the second is connected to the negative of the third, etc. So the batteries are connected: + to + to + and - to - to -. In this configuration, the capacity is the sum of the capacities of the individual batteries and voltage is unchanged. For example, if you take 5 6V 10AH batteries and connect the batteries in series, you would end up with a battery array that is 30 Volts and 10AH. If you connect the batteries in parallel, you would end up with a battery array that is 6 Volts and 50AH. By the way, this is how ordinary auto batteries are made. 6 2volt cells are put in series to give 12v battery and the 6 cells are just enclosed in one case. Many ni-cad batteries are done the same way.
型號 | 標稱電壓 | 額定容量 | 尺寸/重量 | ||||
V | 20hr | 長 | 寬 | 高 | 總高 | 公斤 |
|
PS-1272 | 12 | 7.2 | 151 | 65 | 94 | 98 | 2.40 |
PS-1280 | 12 | 8 | 151 | 65 | 94.5 | 100 | 2.5 |
PSH-1280FR | 12 | 8.5 | 151 | 65 | 94 | 98 | 2.72 |
PS-1282L | 12 | 9 | 196 | 56 | 118 | 118 | 3.13 |
PS-1282S | 12 | 9 | 98 | 112 | 118 | 118 | 3.13 |
PS-1290 | 12 | 9 | 151 | 65 | 94 | 98 | 2.72 |
PS-12100 | 12 | 12.0 | 151 | 102 | 94 | 98 | 3.69 |
PS-12100H | 12 | 10.5 | 151 | 65 | 112 | 118 | 3.28 |
PSH-12100FR | 12 | 10.5 | 151 | 65 | 111 | 117 | 3.18 |
PS-12120 | 12 | 12.0 | 151 | 98 | 94 | 100 | 3.59 |
PS-12120L | 12 | 12.0 | 215 | 70 | 146 | 146 | 3.99 |
PS-12140 | 12 | 14.0 | 151 | 98 | 94 | 100 | 4.09 |
Can I take a wheelchair, scooter or other equipment that is powered by a sealed AGM or Gel battery on a airplane or cruise ship?
Yes. There should be no problem, the battery is considered non-spillable, non-hazardous, since it is a absorbed glass mat design. These sealed lead acid valve regulated (VRLA) batteries are classified as "Battery, wet non-spillable, not subject to regulations" by DOT and IMO. By IATA they are classified as "Not restricted for air transport" and they are in compliance with IATA/ICAO special provision A67. For the gelled electrolyte batteries, they are classified as "Battery, wet, filled with acid, UN2794, Class 8". They can be legally shipped via air with special packaging etc.
How do I Jump Start my Battery using booster cables?
WARNING-BATTERIES PRODUCE EXPLOSIVE GASES. These instructions are designed to minimize the explosion hazard. Keep sparks, flames and cigarettes away from batteries at all times. Both batteries should be of the same voltage (6, 12, etc.).
SAFE BOOSTER CABLE OPERATION When jump starting, always wear proper eye protection and never lean over the battery. Do not jump start a damaged battery; inspect both batteries before connecting booster cables. Be sure vent caps are tight and level. Be sure that the vehicles are not touching and that both ignition switches are in the "OFF" position. Turn off all electrical equipment (radio, defroster, windshield wipers, lights, etc.)
公司一貫堅持“質量*,用戶至上,優質服務,信守合同”的宗旨,憑借著高質量的產品,良好的信譽,優質的服務,產品全國近三十多個省、市、自治區公司與多家零售商和代理商建立了長期穩定的合作關系,公司實力雄厚,重信用、守合同、保證產品質量,以多品種經營特色和薄利多銷的原則,贏得了廣大客戶的信任
前言:
數據中心機房建設要求非常高,國標規范都有哪些要求呢?今天一起來學習一下吧!
正文:
工程中的數據中心機房建設是保證計算機網絡設備和各級勞動保障系統正常運轉的關鍵。現在的計算機設備對運行環境要求較高。因此,必須按照一定的標準規范,科學地設計機房。
一、機房建設需要執行的標準
主機房建設工程必須遵循國家機房設計標準規范的要求。
二、場地要求
計算機機房在多層建筑或高層建筑物內一般應設于第二、三層,水源充足,電力穩定可靠,應遠離產生粉塵、油煙、有害氣體以及貯存具有腐蝕性、易燃、易爆物品的倉庫等;遠離強震源和強噪聲源;避開強電磁場*(如廣播發射臺、雷達站、高壓線等),此外還要具備下列條件:
1、對環境的溫度、濕度要求;
2、對空氣的潔凈度、新鮮度和流動速度要求;
3、對電源、電壓、頻率和穩定性、后備時間要求;
4、對照明的照度、眩光、均勻度、穩定性、顯色性、光效要求及產生有害電磁波的限制及應急照明要求;
5、對各房間樓板荷載要求;
主機房:5.0-7.5KN/m2;配線間及網絡設備間:5.0-7.5KN/m2;電源室:要根據蓄電池擺放形式確定,約為8.0-12KN/m2;一般工作間:2.5KN/m2.
6、對消防、電磁*、安全保密還必須滿足機房工作人員的衛生環境要求和對外的形象要求。
三、機房組成及劃分
1、功能劃分數據中心機房組成應按計算機運行特點及設備具體要求確定,機房面積可根據計算機設備數量或占地面積進行估算。
一般機房設計,除考慮主機房用房外,還要考慮到配置各種輔助用房,具體包括以下幾類:(1)輔助工作間類:如網管監控、終端數據錄入、備份介質存儲等。(2)硬件維護、軟件調試、培訓教室、辦公室等工作用房。(3)配套動力用房:包括配電間、發電機房等。(4)輔助用房:廁所、樓梯、電梯等用房。
2、結構與裝修數據中心機房在結構上應設獨立的出入口,當與其它部門共用出入口時,應避免人流、物流交****;宜設門廳、休息室和值班室。人員出入主機和基本工作間應更衣換鞋。機房與其他建筑物合建時,應單獨設防火分區。計算機房安全出口不應少于兩個,并盡可能設于機房兩端。機房裝修包括地板、吊頂、墻壁裝修以及隔斷、防火金屬門建設;機房裝修要體現機房區域的特點,從內部看,要重點體現高科技的工作環境、嚴謹的科學氣氛、簡潔大方的裝修線條、莊重典雅的裝修色彩、以及以人為本的環保裝修理念。機房裝修要嚴格按照國家相應的標準規范執行。
3、供配電系統根據運行負荷的重要性程度確定供電電源等級。機房電氣系統包括機房區的動力、照明、監控、通訊、維護等用電系統,按負荷性質分為計算機設備負荷和輔助設備負荷,計算機設備和動力設備應分開供電。供配電系統的組成包括配電柜、動力線纜、線槽及插座、接地防雷、照明箱及燈具、應急燈、照明線管。應獨立設置計算機設備配電柜和輔助設備配電柜。
雷擊一般分為直擊雷和感應雷,在機房防雷系統設計中主要避免感應雷,在配電柜進線側面的三條火線、一條零線分別并聯一個過電壓保護裝置。
4、機房空調系統根據數據中心機房環境及設計規范要求,主機房和基本工作間,均應設置空氣調節系統。其組成包括精密空調、通風管路、新風系統。流送回風所采用下送上回、上送下回、上送側回等方式。新風宜采用經溫濕度、潔凈度預處理后的新風,與回風混合后送入機房。
5、機房消防系統機房消防系統由煙感、溫感等消防報警系統及自動滅火系統組成。根據《電子計算機機房設計規范》(GB50174-93),計算機主機房應設置氣體消防滅火系統。一般工作間、輔助間可采用水消防措施。同時,機房應設置火災自動報警裝置和應急廣播。
6、機房環境監控系統機房環境監控系統是對機房中的空調設備、UPS設備、配電柜、空調水管有無漏水、機房環境的溫濕度等環境參數進行集中監測管理的系統,是機房管理人員實現機房科學管理的重要手段。其組成包括空調系統監控、UPS系統監控、配電系統監控、漏水監測系統、溫濕度監測系統。一套好的機房環境監控系統是機房硬件環境系統建設的有利補充,對保障計算機設備正常運行十分必要。
7、機房安全防范系統機房安全防范系統是保障機房安全的重要措施。它對機房內的重點區域進行實時圖像監視和錄像,對出入口實施門禁控制管理和考勤管理,對有可能發生入侵的場所實施報警管理。它由圖像監控系統,門禁系統,防盜報警系統等子系統構成。各子系統之間實行一定的聯動管理控制,以實現更優化的安全防范控制。
8、機房綜合布線系統機房綜合布線系統是架構在機房內部網絡高速路。它連接著機房內部的眾多的網絡設備,并支持語音、圖像、數據等傳輸。綜合布線系統由水平子系統、垂直子系統、管理子系統、設備間子系統和工作區子系統構成。機房內的綜合布線主要為水平布線。但IDC機房中也多采用多模光纖作為數據主干。目前的綜合布線系統多采用超五類或六類系統。按材質又可分為屏蔽系統和非屏蔽系統。
總之,機房建設是一個系統的工程。在設計中要切實做到從工作需要出發,以人為本,滿足功能需要,為設備提供一個安全運行的空間,兼顧美觀實用,為從事計算機操作的工作人員創造良好的工作環境,為金保工程的順利開展打下一個堅實的基礎。
由于網頁資源有限,具體電池型號、參數、價格咨詢請致電。另外我們還為客戶提供技術咨詢服務,說出您的負載、延時時間等,我們會有專業的工程師為您提供ups電源、電池解決方案,讓您真正的后顧無憂!