三级片视频播放,精品三级片在线观看,A级性爱视频,欧美+日韩+国产+无码+小说,亲子伦XX XX熟女,秋霞最新午夜伦伦A片黑狐,韩国理伦片漂亮的保拇,一边吃奶一边做边爱完整版,欧美放荡性护士videos

北京祥生興業科技有限公司

中級會員·8年

聯系電話

13681184382

您現在的位置: 北京祥生興業科技有限公司>>臨床質譜質控品、校準品>>Chromsystems>> 72038 72039類固醇激素校準品
72038 72039類固醇激素校準品
參考價: 面議
具體成交價以合同協議為準
  • 72038 72039 產品型號
  • CHROMSYSTEMS 品牌
  • 代理商 廠商性質
  • 所在地

訪問次數:821更新時間:2025-06-13 14:27:53

聯系我們時請說明是化工儀器網上看到的信息,謝謝!
中級會員·8年
人:
張先生
話:
13681184382
機:
13681184382
址:
北京市北京經濟技術開發區同濟中路甲7號18幢A座1010
化:
www.xiangshengbio.com
址:

掃一掃訪問手機商鋪

產品簡介
供應商:祥生興業規格:7x3ml(lyoph
產品介紹

溫馨提示:僅用于科研,不可用于臨床治療

  • 供應商:

    祥生興業

  • 規格:

    7 x 3 ml (lyoph.)


    72038  6PLUS1® Multilevel Serum Calibrator Set MassChrom® Steroid Panel 1


    Order no.: 72038
    • 11-Deoxycortisol
    • 21-Deoxycortisol
    • Aldosterone
    • Corticosterone
    • Cortisol
    • Cortisone

    MassChrom® Steroids in Serum/Plasma - LC-MS/MS

    DESCRIPTION

    6PLUS1® Multilevel Serum Calibrator Set MassChrom® Steroid Panel 1, lyophilised
    For MassChrom® Steroids in Serum/Plasma with Sample Clean Up Columns or 96 SPE Well Filter Plates.

    These lyophilised calibrators from Chromsystems are based on human serum and should be used according to the instruction manual. They are designed to calibrate the measurement method in clinical diagnostics for the quantitative determination of steroids/Panel 1 in serum/plasma. While following the instructions the calibrators should be handled and measured in the same manner as a patient specimen.
    These calibrators are only available as multilevel calibrator set with 6 different concentration levels plus 1 blank value.

    TECHNICAL DATA

    Method of Analysis

    LC-MS/MS

    Content

    7 x 3 ml (lyoph.)

    Parameter

    11-Deoxycortisol, 21-Deoxycortisol, Aldosterone, Corticosterone, Cortisol, Cortisone

    Concentrations

    Please note: Concentration values shown here are typical. For lot specific concentration values please refer to the product insert supplied with the materials. The product inserts can also be requested from us directly or downloaded from our website after login.

    Substance  Unit Calibrator 1 Calibrator 2 Calibrator 3 Calibrator 4 Calibrator 5 Calibrator 6 Blank Calibrator
    Aldosterone µg/l 0.024 0.084 0.161 0.319 0.816 4.23 n.d. (< 0.014)
    Corticosterone µg/l 0.455 0.997 2.39 4.86 14.9 48.1 n.d. (< 0.175)
    Cortisol µg/l 9.02 20.1 39.1 77.5 149 290 n.d. (< 1.52)
    Cortisone µg/l 0.942 2.56 4.93 9.66 19.5 38.8 n.d. (< 0.148)
    11-Deoxycortisol µg/l 0.088 0.484 0.938 1.87 4.66 13.7 n.d. (< 0.030)
    21-Deoxycortisol µg/l 0.070 0.163 0.257 0.513 1.56 4.69 n.d. (< 0.027)
     
    n.d. = not determined, analytes under LOQ

    Reconstitution

    Carefully remove the metal seal and rubber stopper from the vials. Add exactly 3.0 ml of distilled water into each vial. Return the stopper and incubate for 10 to 15 minutes at room temperature. Swirl the vials to dissolve the contents until homogeneity.

    Storage conditions

    Stored below -18 °C and unopened, the lyophilised calibrators are stable until the expiry date specified on the vial labels. The reconstituted calibrators can be stored up to 10 days light protected and tightly capped at +2 to +8 C. If the calibrators cannot be used within this period, they should be aliquoted and stored frozen below -18 °C (up to 3 months). For more details about storage conditions please check your instruction manual.

     

    72039  6PLUS1® Multilevel Serum Calibrator Set MassChrom® Steroid Panel 2


    Order no.: 72039
    • 11-Deoxycorticosterone
    • 17-OH-progesterone
    • Androstenedione
    • Dehydroepiandrosterone (DHEA)
    • Dehydroepiandrosterone sulfate (DHEA-S)
    • Dihydrotestosterone (DHT)
    • Estradiol
    • Progesterone
    • Testosterone

    MassChrom® Steroids in Serum/Plasma - LC-MS/MS

    DESCRIPTION

    6PLUS1® Multilevel Serum Calibrator Set MassChrom® Steroid Panel 2, lyophilised
    For MassChrom® Steroids in Serum/Plasma with Sample Clean Up Columns or 96 SPE Well Filter Plates.

    These lyophilised calibrators from Chromsystems are based on human serum and should be used according to the instruction manual. They are designed to calibrate the measurement method in clinical diagnostics for the quantitative determination of steroids/Panel 2 in serum/plasma. While following the instructions the calibrators should be handled and measured in the same manner as a patient specimen.
    These calibrators are only available as multilevel calibrator set with 6 different concentration levels plus 1 blank value.

    TECHNICAL DATA

    Method of Analysis

    LC-MS/MS

    Content

    7 x 3 ml (lyoph.)

    Parameter

    11-Deoxycorticosterone, 17-OH-progesterone, Androstenedione, Dehydroepiandrosterone (DHEA), Dehydroepiandrosterone sulfate (DHEA-S), Dihydrotestosterone (DHT), Estradiol, Progesterone, Testosterone

    Concentrations

    Please note: Concentration values shown here are typical. For lot specific concentration values please refer to the product insert supplied with the materials. The product inserts can also be requested from us directly or downloaded from our website after login.

    Substance  Unit Calibrator 1 Calibrator 2 Calibrator 3 Calibrator 4 Calibrator 5 Calibrator 6 Blank Calibrator
    Androstenedione µg/l 0.202 0.408 0.820 1.54 5.09 15.3 n.d. (< 0.020)
    11-Deoxycorticosterone µg/l 0.049 0.098 0.146 0.288 0.721 2.80 n.d. (< 0.023)
    DHEA µg/l 1.04 5.25 10.3 15.6 30.7 60.7 n.d. (< 0.229)
    DHEAS µg/l 117 558 1097 2066 3949 5887 n.d. (< 24.4)
    Dihydrotestosterone µg/l 0.061 0.111 0.257 0.501 0.942 1.50 n.d. (< 0.042)
    Estradiol µg/l 0.043 0.105 0.260 0.530 1.59

    5.33

    n.d. (< 0.026)
    17-Hydroxyprogesterone µg/l 0.097 0.498 1.01 2.00 3.98 15.0 n.d. (< 0.040)
    Progesterone µg/l 0.180 0.805 2.11 5.27 10.3 26.0 n.d. (< 0.030)
    Testosterone µg/l 0.055 0.250 0.982 2.94 5.82 11.6 n.d. (< 0.005)
     n.d. = not determined (< LOQ)

    Reconstitution

    Carefully remove the metal seal and rubber stopper from the vials. Add exactly 3.0 ml of distilled water into each vial. Return the stopper and incubate for 10 to 15 minutes at room temperature. Swirl the vials to dissolve the contents until homogeneity.

    Storage conditions

    Stored below -18 °C and unopened, the lyophilised calibrators are stable until the expiry date specified on the vial labels. The reconstituted calibrators can be stored up to 10 days light protected and tightly capped at +2 to +8 C. If the calibrators cannot be used within this period, they should be aliquoted and stored frozen below -18 °C (up to 3 months). For more details about storage conditions please check your instruction manual.

     

溫馨提示:不可用于臨床治療。


會員登錄

×

請輸入賬號

請輸入密碼

=

請輸驗證碼

收藏該商鋪

X
該信息已收藏!
標簽:
保存成功

(空格分隔,最多3個,單個標簽最多10個字符)

常用:

提示

X
您的留言已提交成功!我們將在第一時間回復您~
產品對比 二維碼 在線交流

掃一掃訪問手機商鋪

對比框

在線留言
主站蜘蛛池模板: 广昌县| 清徐县| 阳东县| 桃园县| 永顺县| 东乌珠穆沁旗| 搜索| 绩溪县| 芦山县| 额敏县| 南昌县| 上高县| 香格里拉县| 尉氏县| 大竹县| 尼木县| 横山县| 尼木县| 乌拉特后旗| 都安| 饶阳县| 凤山县| 蓝山县| 阿鲁科尔沁旗| 鄂伦春自治旗| 当阳市| 乌恰县| 侯马市| 垫江县| 宾川县| 石首市| 资阳市| 繁峙县| 铜川市| 万盛区| 洛隆县| 胶南市| 信阳市| 栾川县| 中宁县| 甘孜县|