三级片视频播放,精品三级片在线观看,A级性爱视频,欧美+日韩+国产+无码+小说,亲子伦XX XX熟女,秋霞最新午夜伦伦A片黑狐,韩国理伦片漂亮的保拇,一边吃奶一边做边爱完整版,欧美放荡性护士videos

| 注冊| 產品展廳| 收藏該商鋪

行業產品

當前位置:
北京恒泰正宇科技有限公司>>技術文章>>BB蓄電池BP24-12 12V24AH光伏發電

產品分類品牌分類

更多分類

BB蓄電池BP24-12 12V24AH光伏發電

閱讀:357        發布時間:2020-2-24

BB蓄電池BP24-12 12V24AH光伏發電

BB蓄電池BP24-12 12V24AH光伏發電

 

With 20 years continuous efforts, in Pan-Asia, Europe, America and Africa, we have successfully established sales channels with strong partnership as well as world-classed OEM clients. The increasing sales amount and quantity demonstrate the healthy escalating growth.

The second production site was founded in Changsha/ China in 2006, where produces full range of AGM and Traction batteries. B.B. Battery commits on China market through its new facilities, determines to deliver the most advanced Lead-Acid battery into this huge emerging market.

生產過程采用全自動化電腦生產線及C.C.D.S充放電檢測系統,保證了產品一致性。
低阻抗設計,自放電性低,容量保持及存儲時間在20℃下可達18個月以上。

全面質量保證
BB已經通過德國TUV機構ISO9001、ISO9002兩項質量認證認證及美國UL認證。產品全部經美國C.C.D.S電腦自動化系統輛次100%充放電檢驗。

環保先鋒
BB在美國有15000個電池回收站,并通過德國TUV機構ISO14001環保認證。成為同時通過ISO9001及ISO14001認證的電池廠商

服務的理念
BB客戶遍及40多個國家和地區。主要客戶有:APC、EXIDE、DELTEC、DELTA、SIEMENS、ERICSSON、PCM、MGR、BEST、LIEBERT等。

 BB蓄電池電槽外殼經超音波特殊密封,置放時不受方向、位置之限制,除依印刷字體方向置放外,亦可以倒立放置、橫向放置等各種放置方式,均不影響其安全與功能。 以特殊配方的鉛鈣合金及全自動化制造,品質穩定產品不會產生危險氣體。

    對于普通用戶,在選購UPS時必須考慮技術性能、服務保證和產品價格,三大因素需綜合平衡、統籌兼顧。目前,可供信息網絡應用的UPS品種很多,我們一般所指的UPS大都為靜止變換式,它可分為后備式、在線式、在線互動式三大類。現在在國內UPS市場繁榮的背后,泥砂俱下,所以在選購時要注意以下問題:

    (1)不要過分追求對UPS常規電性能指標的要求,諸如轉換時間、電壓和頻率穩定度、波形失真度等。應該重視對UPS輸出能力和可靠性的考察。

    (2)根據計算機設備的型號、規格及具體要求選擇UPS,注意兩者的匹配性能和兼容能力。

    (3)依照需保護的項目和內容來選擇UPS,科學計算UPS的功率,保證功率值準確。

    (4)選擇能夠提供優質售后服務的供應商,注意產品的品牌。

    (5)全面考慮負載設備所處理信息的重要程度,各種用電設施對電源質量的要求,電源安裝與空間要求及投資規模等。

    (6)為聯網設備選擇UPS時,應重點考慮電源管理軟件的網絡管理能力和跨平臺管理能力。

    (7)為電信設備選購UPS時,應重點考慮UPS帶非線性負載的能力,對噪聲的抑制能力及高可靠性。

    不同的用戶對UPS類型的需求也是不同的,個人及家庭用戶可以考慮后備式UPS,它價格低廉,外形輕巧,是個人電腦的理想伙伴。而企業、事業用戶可以選購后備式UPS,也可考慮在線式UPS或在線互動式UPS。在選購UPS時應針對機房使用計算機的臺數,向商家詢問適合本系統的UPS容量。目前國內常見的LIPS品牌有APC、山特、梅蘭日蘭、實達、華為等。

Model

Voltage

Nominal Capacity

Weight

Terminal

Dimension

Model

15 Min W/Cell

10hr Ah

Kg

Lbs

Standard

Optional

L

W

H

TH

Type

Position

Type

Position

MM

INCH

MM

INCH

MM

INCH

MM

INCH

HR9-6

6

36

8

1.40

3.09

T2

2

T1

 

151

5.94

34

1.34

  94

3.70

100

3.94

HR9-6

HR4-12

12

16

3.5

1.40

3.09

T1

3

T2

 

134

5.28

67

2.64

  60

2.36

  66

2.60

HR4-12

HR5.5-12

12

22

5

1.80

3.97

T1

3

T2

 

  90

3.54

70

2.76

102

4.02

106

4.17

HR5.5-12

HR5.8-12

12

23

5.3

1.88

4.15

T1

3

T2

 

  90

3.54

70

2.76

102

4.02

106

4.17

HR5.8-12

HR6-12

12

24

5.5

2.10

4.63

T1

5

T2

 

151

5.94

51

2.01

  94

3.70

100

3.94

HR6-12

HR8-12

12

32

7

2.60

5.73

T2

5

T1

 

151

5.94

65

2.56

  94

3.70

100

3.94

HR8-12

HR9-12

12

36

8

2.75

6.06

T2

5

T1,B0

 

151

5.94

65

2.56

  94

3.70

100

3.94

HR9-12

HR15-12

12

60

13

4.20

9.26

T2

5

 T1

 

151

5.94

98

3.86

  94

3.70

98

3.86

HR15-12

HR22-12

12

88

20

6.50

14.33

B1

7

T2,I1

6

181

7.13

76

2.99

166

6.54

166

6.54

HR22-12

HR33-12

12

132

31

10.00

22.05

B1

7

T2,I1

9

175

6.89

166

6.54

125

4.92

125

4.92

HR33-12

HR40-12S

12

160

38

12.10

26.68

B7

8

 

 

195

7.68

129

5.08

155

6.10

179

7.05

HR40-12S

HR40-12H

12

160

38

12.10

26.68

B7

8

 I2

 

210

8.27

129

5.08

168

6.61

179

7.05

HR40-12H

HR40-12F

12

160

38

12.10

26.68

B7

8

 I2

 

195

7.68

129

5.08

168

6.61

179

7.05

HR40-12F

HR50-12

12

200

48

15.30

33.74

B2

7

I1,I2

 

197

7.76

165

6.50

171

6.73

171

6.73

HR50-12

HR75-12

12

300

73

24.75

54.57

B5

15

I2

 

350

13.78

166

6.54

174

6.85

174

6.85

HR75-12

免維護蓄電池荷電出廠,從出廠到安裝使用,電池容量會受到不同程度的損失,若時間較長,在投入使用前應進行補充充電。如果蓄電池儲存期不超過一年,在恒壓2.27V/只的條件下充電5天。如果蓄電池儲存期為1~2年,在恒壓2.33V/只條件下充電5天。

蓄電池浮充使用時,應保證每個單體電池的浮充電壓值為2.25~2.30V,如果浮充電壓高于或低于這一范圍,則將會減少電池容量或壽命;

蓄電池浮充運行時,蓄電池單體電池電壓不應低于2.20V,如單體電壓低于2.20V,則需進行均衡充電。均衡充電的方法為:充電電壓2.35V/只,充電時間12小時;

UPS應用中的注意事項

    UPS在使用時必須遵守其操作規程,并應注意以下事項:

    (1)UPS要防止陽光直射,要留足夠的通風空間。

    (2)使用UPS時,務必遵守產品說明書中的有關規定,保證所接的火線、零線、地線的要求,用戶不

  得隨意改變其相互的順序。

    (3)嚴格按照正確的開機、關機順序進行操作。避免因突然加載或減載時,UPS的電壓輸出波動過大,而無法正常工作。

    (4)嚴禁頻繁地關閉和開啟UPS。一般要求在關閉UPS后,至少等待6秒鐘才能重新開啟,否則,UPS可能進入“啟動失敗”的狀態,即UPS進入既無市電輸出,又無逆變輸出的狀態。

    (5)禁止超負載使用。UPS的大啟動負載控制在80%之內,如果超載使用,在逆變狀態下,時常會擊穿逆變三極管。實踐證明:對于絕大多數UPS而言,將其負載控制在30%-60%額定的輸出功率范圍內是工作方式。

    (6)定期對UPS進行維護工作。清除機內的積塵,測量蓄電池組的電壓,更換不合格的電池,檢查風扇運轉情況及檢測調節UPS的系統參數等。

蓄電池循環使用時,在放電后采用恒壓限流充電。充電電壓為2.35~2.45V/只,大電流不大于0.25C20 具體充電方法為:先用不大于上述大電流值的電流進行恒流充電,待充電到單體平均電 壓升到2.35~2.45V時改用平均單體電壓為2.35~2.45V恒壓充電,直到充電結束;電池循環使用時充電*的標志:在上述限流恒壓條件下進行充電,其充足電的標志,可以在以下兩條中任選一條作為判斷依據:⑴充電時間18~24小時(非深放電時間可短)。⑵充電末期連續三小時充電電流值不變化。⑶ 恒壓2.35~2.45V充電的電壓值,是環境溫度為25℃的規定值。當環境溫度高于25℃時,充電電壓要相應降低,防止造成過充電。當環境溫度低于25℃時,充電電壓應提高,以防止充電不足。通常降低或提高的幅度為每變化1℃每個單體增減0.005V;

蓄電池放電后應立即再充電,若放電后的蓄電池擱置時間太長,即使再充電也不能恢復其原容量;

電池使用時,務必擰緊接線端子的螺栓,以免引起火花及接觸不良。