P+F Engineering Process Fieldbus Installations

The fieldbus infrastructure constitutes the backbone of your automation system. Design rules apply analogous to any electrical installation. The following engineering criteria are important for reliability and cost-effectiveness:

 

  • Choices such as redundancy or protection from short-circuits, power surges, or water ingress
  •  Methods of ignition protection typical for fieldbus installations in Zones and Divisions 

 

Topology and components—simplicity for engineering and handling

A segment is a single circuit with power supply, fieldbus junction boxes, and instruments. The segment connects the control system to multiple instruments. The topology design determines the physical location and connection of power supplies, fieldbus junction boxes, and instruments.

The typical topology for a segment is the trunk-and-spur topology with a main line or master cable (trunk). The trunk connects the power supplies and communication interfaces located in the control room with the field. One or more fieldbus junction boxes mounted where they are easily accessible provides connections for field devices. The connection cable with a length of up to 120 m is called a spur, as it is typically much shorter in comparison to the trunk. This topology fits practically all process plants.

With its many similarities to the topologies known from multi-core trunk cables leading to a fieldbus junction box installed in the field, the trunk-and-spur? topology is easy to understand, engineer, and maintain.

 


Trunk-and-spur topology provides simplicity by design. Each device is connected separay.

The fieldbus junction box is also called the device coupler. Where it is required, ignition protection is scalable through a selection of power supplies and device couplers. This enables economic solutions for any hazardous area.

 

Download Segment Checker—the easy to use segment design tool

Download and install the free software tool to easily design and layout your fieldbus segments as well as engineer cable lengths based on the devices you use. Device libraries let you choose the instruments of your favorite manufacturer. Make fieldbus installation a simple click process …

 

Function and availability

Modern-day device couplers provide reliable protection from typical working conditions such as device exchange, contact bounce, water ingress or power surges, etc. These functions are described in detail here …

FieldConnex simplifies engineering and implementation of fieldbus installations for any process plant in any industry with selections and options for protection from ambient conditions, and for the right availability.

See all fieldbus components for use in non-explosion hazardous areas and find the right components for your plant here …

 

 

Fieldbus in hazardous areas

Fieldbus in hazardous areas requires an infrastructure with ignition protection. See below the topology for any hazardous area: Read the details on methods of ignition protection here …

 


Identical topology with trunk and spurs for any hazardous area. Selecting the components and installation methods provides ignition protection.

免責聲明

  • 凡本網注明“來源:化工儀器網”的所有作品,均為浙江興旺寶明通網絡有限公司-化工儀器網合法擁有版權或有權使用的作品,未經本網授權不得轉載、摘編或利用其它方式使用上述作品。已經本網授權使用作品的,應在授權范圍內使用,并注明“來源:化工儀器網”。違反上述聲明者,本網將追究其相關法律責任。
  • 本網轉載并注明自其他來源(非化工儀器網)的作品,目的在于傳遞更多信息,并不代表本網贊同其觀點和對其真實性負責,不承擔此類作品侵權行為的直接責任及連帶責任。其他媒體、網站或個人從本網轉載時,必須保留本網注明的作品第一來源,并自負版權等法律責任。
  • 如涉及作品內容、版權等問題,請在作品發表之日起一周內與本網聯系,否則視為放棄相關權利。
企業未開通此功能
詳詢客服 : 0571-87858618
主站蜘蛛池模板: 南丹县| 嘉禾县| 云浮市| 萨迦县| 吴忠市| 靖江市| 榆中县| 古丈县| 宁夏| 崇州市| 洞头县| 崇文区| 庆城县| 噶尔县| 泸西县| 壤塘县| 多伦县| 锦屏县| 鹿邑县| 寿阳县| 衡东县| 德钦县| 和平区| 宁阳县| 昌宁县| 辉县市| 蒲城县| 合水县| 资溪县| 如东县| 依安县| 英超| 青海省| 凉城县| 临高县| 鸡东县| 佛山市| 庄河市| 卓资县| 桃园市| 和硕县|