FLTM BO 116-01_2007

來源:東莞市勤卓環境測試設備有限公司   2019年08月27日 08:26  

FLTM BO 116-01_2007

本頁面標準信息均來源于網絡收集,或由參與標準制定的供應商提供,只作為參考使用,為確保測試結果的準確性、節省您的時間,如需FLTM BO 116-01_2007標準詳細信息或FLTM BO 116-01_2007具體測試方法,請與我們技術人員聯系或給我們留言,我們將為您提供相關的技術支持。

 

FLTM-BO-116-01標準簡介

FLTM-BO-116-01 汽車內飾材料暴曬試驗標準:水冷式氙弧燈氣候試驗箱方法

FLTM  BO 116-01_2007標準英文版

EXPOSRE OF INTERIOR TRIM MATERIALS IN A CONTROLLED IRRADIANCE

WATER COOLED XENON-ARC APPARATS

Application

This procedure is used to determine the effects of simulated weather on interior trim materials using a controlled irradiance water cooled xenon-arc Weather-Ometer® with an auxiliary lantern and filters.

Apparatus Required

Operating Filter

335 nm long pass filters (SF-5 filters) or equivalent provided the transmission spectrum is within 95% of the SF-5 filter transmission at all wavelengths. The filters are reversible unless otherwise marked by a coating or etching.

Dimensions for the Ci 5000 series Weather-Ometer®:

339 mm +/- 0.13 mm x 70 mm +/- 0.13 mm x 3 mm +/- 0.52 mm

Dimensions for the Ci 3, Ci 6 & Ci 4000 Weather-Ometer®:

220 mm +/- 0.13 mm x 70 mm +/- 0.13 mm x 3 mm +/- 0.52 mm

Lamp Sensor Irradiance Filter

420 nm Irradiance Filter

Available from:

Atlas Material Testing Technology LLC

4114 Ravenswood Ave.

Chicago, IL 60613 SA

Calibration Lamp

The calibration lamp must be calibrated to 420 nm with the lantern assembly removed.

Available from:

Atlas Material Testing Technology LLC

4114 Ravenswood Ave.

Chicago, IL 60613 SA

Sample & Test Conditions

Sample Conditioning

All test values indicated herein are based on material conditioned in a controlled atmosphere of 21 +/-2 °C and 50 +/- 5% relative humidity for not less than 24 h prior to testing and tested under the same conditions unless otherwise specified.

Test Conditions

Testing conditions such as black panel temperature, dry bulb temperature, humidity, light cycle times and dark cycle times are equivalent to those outlined in SAE J2412 – Accelerated Exposure of Automotive Interior Trim Components sing a Controlled Irradiance Xenon-Arc Apparatus, Table 1,Section 6.1.5.

Place the 335 nm long pass filters (SF-5 filters) or equivalent into the auxiliary lantern. Orient thelantern around the xenon-arc lamp assembly which is equipped with the Quartz/Type "S" Borosilicate filtered xenon-arc lamp source as outlined in SAE J2412 – Accelerated Exposure of Automotive Interior Trim Components sing a Controlled Irradiance Xenon-Arc Apparatus, Apparatus Set-p, Section 6.

Exposures are monitored based on measured light at 1.06 W/m2 -/nm@420 nm SAE J2412 –Accelerated Exposure of Automotive Interior Trim Components sing a Controlled Irradiance XenonArc Apparatus, Table 1.

Calibration

Equipment Calibration

As per SAE J2412 – Accelerated Exposure of Automotive Interior Trim Components sing a Controlled Irradiance Xenon-Arc Apparatus, Appendix A, Section A.3 and Appendix B.

Maintenance

Equipment Maintenance

As per SAE J2412 – Accelerated Exposure of Automotive Interior Trim Components sing a Controlled Irradiance Xenon-Arc Apparatus, Appendix A.

Note: SF-5 auxiliary filters should be cleaned at every lamp calibration period or more frequent if necessary.

SF-5 filters and the 420 nm interference filter should be changed per the manufacturer's recommendations/or within 13,000 hours of use.

Exposure

Sample Exposure

As per SAE J2412 – Accelerated Exposure of Automotive Interior Trim Components sing a Controlled Irradiance Xenon-Arc Apparatus, Test Procedure, Section 7.

Evaluation & Reporting

Sample Evaluation and Exposure Report

As per SAE J2412 – Accelerated Exposure of Automotive Interior Trim Components sing a Controlled Irradiance Xenon-Arc Apparatus, Evaluating and Reporting, Section 8 and Exposure Report, Section 9.

AATCC Gray Scale, 10 Step, According to AATCC Evaluation Procedure 1/ISO 105-A02 for Evaluation of Color Change.

FLTM BO II--01_2007測試機構

 

pon request measure the gloss with a 60° glossmeter (or as specified in the applicable Engineering Standard) according to FLTM BI 110-01. Record the unexposed and exposed gloss.

Chemicals, materials, parts and equipment referenced in this document must be used and handled properly. Each party is responsible for determining proper use and handling in its facilities.

免責聲明

  • 凡本網注明“來源:化工儀器網”的所有作品,均為浙江興旺寶明通網絡有限公司-化工儀器網合法擁有版權或有權使用的作品,未經本網授權不得轉載、摘編或利用其它方式使用上述作品。已經本網授權使用作品的,應在授權范圍內使用,并注明“來源:化工儀器網”。違反上述聲明者,本網將追究其相關法律責任。
  • 本網轉載并注明自其他來源(非化工儀器網)的作品,目的在于傳遞更多信息,并不代表本網贊同其觀點和對其真實性負責,不承擔此類作品侵權行為的直接責任及連帶責任。其他媒體、網站或個人從本網轉載時,必須保留本網注明的作品第一來源,并自負版權等法律責任。
  • 如涉及作品內容、版權等問題,請在作品發表之日起一周內與本網聯系,否則視為放棄相關權利。
企業未開通此功能
詳詢客服 : 0571-87858618
主站蜘蛛池模板: 海盐县| 五莲县| 莲花县| 南岸区| 西乌珠穆沁旗| 泊头市| 永胜县| 方正县| 仁化县| 贡山| 探索| 牙克石市| 博罗县| 南乐县| 都昌县| 乳源| 墨脱县| 大田县| 杭锦旗| 忻城县| 彩票| 福州市| 元阳县| 根河市| 得荣县| 沧源| 车险| 阳原县| 安国市| 和林格尔县| 九寨沟县| 岢岚县| 民丰县| 车险| 平罗县| 江永县| 石屏县| 延庆县| 精河县| 渭源县| 青铜峡市|